How long would your backup power last?

Flip on the circuits you can't lose. We check output, start-up surge and 240 V, then play the outage hour by hour for a power station, a home battery and your EV.

Free · no sign-up · specs checked October 28, 2026

Some links on this page are affiliate links: we may earn a commission if you buy, at no extra cost to you. It never changes a runtime or a pick. How we make money.

Your breaker panel

4 circuits on
  • Refrigerator

    700 W run · 2.9 kW start

    Qty
    1

    700 W covers the compressor and defrost peaks; real use is about 1 kWh a day for an ENERGY STAR model.

  • Chest freezer

    700 W run · 2.9 kW start

  • Microwave

    1.0 kW run

  • Coffee maker

    1.0 kW run

  • Hot plate / one burner

    1.3 kW run

  • Dishwasher

    1.2 kW run · 2.4 kW start

Outage length

Your result

1002005001k2k5k10k20kWATTSLOG · 120/240 V ACLOAD METER
Running at once
790 W
Starting peak
3.0 kW
Energy per day
1.7 kWh
Voltage
120 V
needle = running · red = start-up peak of your refrigerator. Bands: green ≤ 1.8 kW (1 kWh stations), amber ≤ 7.2 kW (largest portables), red beyond.

Jackery HomePower 2000 Plus v2

Lasts the full 24 h

with 5% left when the grid comes back.

100%+6h+12h+18hGRID DOWNGRID BACK
Battery level through the outage. Background = your sky (night, dawn, day).
  • EcoFlow DELTA 3 Plus + 1 × DELTA Pro 3 Smart Extra Battery (one at a time)

    Covers your list · 5.1 kWh · 1.8 kW out · 3.6 kW surge

  • Jackery HomePower 2000 Plus v2

    Covers your list · 2.0 kWh · 2.4 kW out · 4.8 kW surge

    24 h+$1,069
  • Jackery HomePower 3600 Plus

    Covers your list · 3.6 kWh · 3.6 kW out · 7.2 kW surge

    24 h+$1,709
  • BLUETTI Apex 300

    Covers your list · 2.8 kWh · 3.8 kW out · surge not published

    24 h+$1,599
  • Anker SOLIX F3800 Plus

    Covers your list · 3.8 kWh · 6.0 kW out · surge not published

  • EcoFlow DELTA Pro 3

    Covers your list · 4.1 kWh · 4.0 kW out · 8.0 kW surge

    24 h+$2,799
  • Jackery HomePower 3600 Pro Max

    Covers your list · 3.6 kWh · 4.0 kW out · 8.0 kW surge

    24 h+$1,799
  • Jackery Explorer 5000 Plus

    Covers your list · 5.0 kWh · 7.2 kW out · 14 kW surge

    24 h+$3,149
  • Anker SOLIX F2000

    Can't start your biggest motor · 2.0 kWh · 2.4 kW out · surge not published

  • BLUETTI AC180

    Can't start your biggest motor · 1.2 kWh · 1.8 kW out · surge not published

    —$499
  • Jackery Explorer 1000 v2

    Runs it, but not for the whole outage · 1.1 kWh · 1.5 kW out · 3.0 kW surge

    13 h$499
  • Anker SOLIX C1000 Gen 2

    Runs it, but not for the whole outage · 1.0 kWh · 2.0 kW out · 3.0 kW surge

Free · no spam

Email me this plan

Your list, the unit that covers it and a reminder to top up the battery before storm season.

How the planner decides

A backup fails in one of three ways, and the planner checks all three before it shows a runtime. First, continuous output: everything you switched on can run at the same time, so the unit has to deliver the sum of their running watts. Second, starting power: the largest motor on your list (sump pump, well pump, furnace blower, compressor) needs a short kick of two to three times its running watts. Third, voltage: well pumps, central AC, dryers and electric water heaters run on 240 V, which most portable stations don't provide without a second unit or the maker's home panel.

Only then does energy come in. The planner drains the battery at your average draw plus inverter losses, quarter-hour by quarter-hour, starting at the hour you set for the outage, and adds solar during daylight. That is why an outage that starts at 6 p.m. and one that starts at 9 a.m. can end differently with the same panels.

Make it match your house

  • Open a circuit and type the watts printed on your appliance's label: the start-up surge scales with it.
  • Hours are hours of actual running. A sump pump in a storm might run 10 minutes an hour, which is about 4 hours a day.
  • For central AC, the deciding number is the LRA (locked-rotor amps) on the outdoor unit's label. Compare it to the battery's rating: a Powerwall 3 is rated for 185 LRA.

Every appliance links to the source of its numbers, and every product spec carries its check date on the power station page. The full method is on our about page.

Questions people ask

How do I calculate how much backup power I need?

Add the running watts of everything that may be on at once (that's the continuous output you need), add the biggest single motor's start-up kick on top (that's the surge), then multiply each appliance's watts by its hours of use to get watt-hours per day. Divide the battery's capacity by your average draw, after about 10–12% inverter losses, for the runtime.

Why does my fridge show 700 W but only about 1 kWh a day?

Because a compressor cycles. 700 W is the conservative running figure generator makers use to size for start-up and defrost; the actual energy an ENERGY STAR refrigerator uses is about 1 kWh per day. The planner uses the first number to check output and the second to compute runtime.

What does 'can't start your biggest motor' mean?

Pumps, compressors and blowers draw two to three times their running power for a fraction of a second when they start. If a unit's surge rating is below that peak, it shuts off or refuses to start the motor even with a full battery. When a maker doesn't publish a surge rating, we only count its continuous output.

Do you include solar?

Yes, if you add panels. Solar follows a sine curve from 6 a.m. to 6 p.m. at 75% of the panels' rating, the equivalent of about 5.7 hours at the panels’ full rating on a clear day, and is capped by each unit's solar input. Storm days produce less, so treat solar as a bonus.

Can I connect a power station to my house wiring?

Only through a transfer switch, an interlock kit or the maker's home panel, installed by a licensed electrician. Never plug a power station or car into a wall outlet to feed the house: it can electrocute utility workers and neighbors.